Upgrade the system software S5300

Select 2. Download file to Flash through serial interface in the serial interface submenu, and the following information is displayed:
Enter your choice(1-4): 2

Please Select File.
XMODEM downloading ...CC
Choose Transfer > Send File. The Send File dialog box is displayed.
Click Browse to select the upgrade file of the system software. Then select Xmodem from the Protocol drop-down list box. Click Send to start sending the file.
After transferring the upgrade file, the system prompts you whether to change the file name. If no, save it with the default file name. The default file name is not the uploaded file name. The system software name in the flash memory or the default file name hw-switch.cc is used. Generally, it is recommended that the file name be changed.

Only the files with the file name extension .cc can be used as the upgrade files of the system software on the LS-S5328C-PWR-SI
If you need to name the upgrade file S5300EI-V200R003C00SPC300.cc, the following information is displayed:
XMODEM downloading ...CC   download succeeded!
Do you like to save it named "S5300EI-V200R003C00SPC300.cc"?
If you like then press return key, otherwise give a new name for saving it:
S5300EI-V200R003C00SPC300.cc
If the file S5300EI-V200R003C00SPC300.cc has already been saved in the flash memory, the system prompts you whether to overwrite the existing file with the new one. The following information is displayed:
flash:/S5300EI-V200R003C00SPC300.cc already exist,
delete it?(Y/N):y
Deleting file.......................................done
took time : 251s
Writing Flash.............................................................................................................................................................................done

file length: 14,066,348 bytes, took time : 244s

          SERIAL  SUBMENU

    1. Update BOOTROM system
    2. Download file to Flash through serial interface
    3. Modify serial interface parameter
    4. Return to main menu

Enter your choice(1-4):

After the S5348TP-SI upgrade file is transferred, select 4. Return to main menu to return to the BootROM menu.

2013年11月27日星期三

S3328TP-PWR-EI VS LS-S3352P-PWR-EI, The Difference

 What are the difference of S3328TP-PWR-EI and LS-S3352P-PWR-EI?

Huawei Quidway Switch S3300, S3328TP-PWR Mainframe(24 10/100 BASE-T ports and 2 Combo GE(10/100/1000 BASE-T+100/1000 Base-X) ports and 2 SFP GE(1000 BASE-X) ports,PoE,Chassis,Double Slots of power,Without Power)

Huawei Quidway Switch S3300, S3352P-PWR Mainframe(48 10/100 BASE-T ports and 2 100/1000 BASE-X ports and 2 SFP GE(1000 BASE-X) ports,PoE,Chassis,Double Slots of power,Without Power)

 The S3300 provides the enhanced selective QinQ function and capability to replicate multicast packets between VLANs at the line speed, and supports carrier-class reliability technologies such as Smart Link (applicable to tree networks) and RRPP (applicable to ring networks), as well as the Ethernet OAM function.

The difference on the price:
According to our research, www.huanetwork.com is a great wholesell supplier for huawei switch, and the best price form.
S3328TP-PWR-EI price : $891.00
LS-S3352P-PWR-EI price : $1,485.00

Request a quote for them by emailing us at sales@huanetwork.com or pick up the phone and speak to one of our friendly and helpful sales reps at +852-30501940 (Hong Kong).

2013年11月25日星期一

Checking the Current System Software Version

Run the display version command to view the version of the system software.
<Quidway> display version
Huawei Versatile Routing Platform Software                                     
VRP (R) software, Version 5.120 (S5300 V200R002C00SPC100)                            
Copyright (C) 2000-2012 HUAWEI TECH CO., LTD                                   
Quidway S5328C-PWR-EI Routing Switch uptime is 0 week, 0 day, 0 hour, 16 minutes
                                                                               
CX22EFGEE 0(Master) : uptime is 0 week, 0 day, 0 hour, 15 minutes              
256M bytes DDR Memory                                                          
32M bytes FLASH                                                                
Pcb      Version :  VER A                                                       
Basic  BOOTROM  Version :  160 Compiled at Dec 18 2012, 16:07:05               
CPLD   Version : 79                                                            
Software Version : VRP (R) Software, Version 5.120 (V200R002C00SPC100)                
FORECARD information                                                           
Pcb      Version : CX22E2XX VER B                                              
HINDCARD information                                                            
Pcb      Version : CX22ETPC VER B                                              
FANCARD I information                                                          
Pcb      Version : FAN VER B                                                   
PWRCARD I information                                                          
Pcb      Version : PWR VER A     


In the preceding output, S5300 V200R002C00SPC100 indicates the version of system software currently running on the S5352C-EI

2013年11月14日星期四

Huawei S3300 switch Upgrade Process

On the master switch S3352P-EI-48S :
In Stack, device 0 load to new device 1 .......... start

In Stack, device 0 load to new device 1 .......... success
On the new member switch:
The Software Version is Low.Version is V100R006C00SPC800!
100% completed
In Stack, device 0 load flash:/S5300EI-V200R001C00SPC300.CC to new device 1(self) ... Success
Starting upgrade BOOTROM .............. Pass

Device starting reset.

If the flash memory of the new member switch does not have sufficient space for the upgrade software, the following information is displayed:
On the master switch:
In Stack, device 0 load to new device 1 .......... start

In Stack, device 0 load to new device 1 .......... fail
On the new member switch:
In Stack, upgrading from slot 4 to slot 0(self) .......... start               
Info: Free space is not enough. Auto deleting <flash:/S5300EI-V100R006C00SPC800.cc> file ....
................................................................................
........................... success                                            
                                                                                
 100% completed                                               


For more Huawei S3328TP information please click here

2013年11月11日星期一

How to configure the MTU for an Ethernet Interface on Huawei NE20E Router?

Huanetwork.com offers Huawei Quidway NetEngine20E Series Routers, NE20E routers are high-end routers which famous for high forwarding performance, abundant services and carrier-class reliability. The NE20E router adopts the network processor (NP) technology which takes advantages of both ASIC and CPU, it can provide both high hardware-based performance (4.5Mpps) and software-based flexibility. Huanetwork.com ships Huawei NE20E router to worldwide.

Step 1:
system-view
The system view is displayed.
Step 2:
interface gigabitethernet interface-number
The specified Ethernet interface view is displayed.
Step 3:
mtu mtu
An IPv4 MTU is set for the Etherent interface.
Step 4:
commit
The configuration is committed.
Step 5:
system-view
The system view is displayed.
Step 6:
interface gigabitethernet interface-number
The specified Ethernet interface view is displayed.
Step 7:
ipv6 enable
IPv6 is enabled on the Ethernet interface.
Step 8:
ipv6 mtu mtu
An IPv6 MTU is set for the Ethernet interface.
Step 9:
commit
The configuration is committed.

For more Huawei information please click here
http://www.huanetwork.com/gpon-epon-terminal-price_c42

How to configure RMON Statistics Functions on Huawei LS-S5328C-EI-24S switch?

Huawei Quidway Switch S5300, LS-S5328C-EI-24S Mainframe(20 100/1000Base-X ports 4 gigabit Combo ports, and supports 2 10GE XFP subcards, 4 1000Base-X SFP subcards, 2 10GE SFP+subcards, and 4 10GE SFP+subcards,Dual Slots of power,Without Flexible Card and Power Module)

Step 1:
system-view
The system view is displayed.
Step 2:
interface { ethernet | gigabitethernet | xgigabitethernet | 40GE } interface-number
The interface view is displayed.
Step 3:
rmon-statistics enable
RMON statistics function is enabled on an interface.
Step 4:
rmon statistics entry-number [ owner owner-name ]
A statistics table is created and an entry is added to the table.
Step 5:
system-view
The system view is displayed.
Step 6:
interface { ethernet | gigabitethernet | xgigabitethernet | 40GE } interface-number
The interface view is displayed.
Step 7:
rmon-statistics enable
RMON statistics function is enabled on an interface.
Step 8:
rmon history entry-number buckets number interval sampling-interval  [ owner owner-name  ]
A history control table is created and an entry is added to the table.


For more Huawei information please click here

http://www.huanetwork.com/huawei-me60-x3-me0p03basd30-price_p1691.html

2013年11月7日星期四

How to configure a RADIUS Accounting Server on Huawei S3300 switch?

LS-S3328TP-SI-AC,Huawei Quidway Switch S3300, S3328TP-SI Mainframe(24 10/100 BASE-T ports and 2 Combo GE(10/100/1000 BASE-T+100/1000 Base-X) ports and 2 SFP GE (1000 BASE-X) ports (SFP Req.) and AC 110/220V)

Step 1:
system-view
The system view is displayed.
Step 2:
radius-server template template-name
The RADIUS server template view is displayed.
Step 3:
radius-server accounting ip-address port [ source loopback interface-number ]
The primary RADIUS accounting server is configured.
Step 4:
radius-server accounting ip-address port [ source loopback interface-number ] secondary
The secondary RADIUS accounting server is configured.

For more Huawei EPON information please click here

2013年11月6日星期三

How to configure the Static DNS Service on a DHCP Client on Huawei S2309TP-SI switch?

Huawei Quidway Switch S2300, S2309TP-SI Mainframe(8 10/100 BASE-T ports and 1 Combo GE(10/100/1000 BASE-T+100/1000 Base-X) ports and AC 110/220V)

The Quidway S2300 series switches are new generation Ethernet intelligent access switches. The S2300 is mainly deployed on the IP MAN and intranets, meeting requirements of carrying various Ethernet services and accessing the Ethernet. Based on the new generation high-performance hardware and Huawei Versatile Routing Platform (VRP), the S2300 supports rich and flexible service features and thus improves the operability, manageability, and service expansibility. In addition, the S2300 supports powerful lightning protection, security features, ACLs, QinQ, 1:1 VLAN switching, and N:1 VLAN switching to flexibly deploy VLANs.

Step 1:
system-view
The system view is displayed.
Step 2:
interface interface-type interface-number
The interface view is displayed.
Step 3:
dhcp server domain-name domain-name
The domain name to be allocated to a DHCP client is configured.
Step 4:
dhcp server dns-list ip-address &<1-8>
The IP address of the DNS server is configured for a DHCP client.

For more Huawei MA5600T information please click here

2013年11月4日星期一

How to configure Remote MAC Address Mirroring on Huawei S3328TP-EI Switch?

Huawei Quidway Switch S3300, S3328TP-EI Mainframe(24 10/100 BASE-T ports and 2 Combo GE(10/100/1000 BASE-T+100/1000 Base-X) ports and 2 SFP GE (1000 BASE-X) ports (SFP Req.)2 MC ports,AC 110/220V)

Step 1:
system-view
The system view is displayed.
Step 2:
vlan vlan-id
An RSPAN VLAN is created and the RSPAN VLAN view is displayed.
Step 3:
mac-address learning disable
The MAC address learning is disabled.
Step 4:
quit
Return to the system view.
Step 5:
observe-port index interface interface-type interface-number [ vlan vlan-id ]
An observing port is configured, and the RSPAN VLAN is specified.
Step 6:
vlan vlan-id
The view of the VLAN that the observed MAC address belongs to is displayed.
Step 7:
mac-mirroring mac-address to observe-port index inbound
Remote MAC address mirroring is configured and the RSPAN VLAN is specified.


For more Huawei LS-S5328C-PWR-SI information please click here

How to configure the Peer Mode on Huawei Switch?

Huawei Quidway Switch S2300, S2309TP-EI Mainframe (8 10/100 BASE-T ports and 1 Combo GE (10/100/1000 BASE-T+100/1000 Base-X) ports and AC 110/220V)

Step 1:
system-view
The system view is displayed.
Step 2:
ntp-service source-interface vlanif vlan-id
The local source interface that sends NTP packets is specified.
Step 3:
ntp-service unicast-peer ip-address [ version number | authentication-keyid key-id | source-interface interface-type interface-number | preference ] *
The NTP peer is configured.
Step 4:
system-view
The system view is displayed.
Step 5:
ntp-service source-interface vlanif vlan-id
The local source interface that sends NTP packets is specified.

For more Huawei LS-S2309TP-EI-AC information please click here